²úÆ·Ïêϸ½éÉÜNeurOne¸ß¾«¶ÈÄÔµç²âÁ¿ÏµÍ³
Ò»¡¢²úÆ·¸ÅÊö£º NeurOneEEG/ERP¸ß¾«¶ÈÄÔµç²âÁ¿ÏµÍ³ÊÇ·ÒÀ¼Mega¹«Ë¾¿ª·¢µÄ´´ÐÂÐÍÄÔ¿ÆÑ§Ñо¿£¬NeurOneÈÏÖªÉñ¾¿ÆÑ§²âÁ¿ÏµÍ³ÀûÓÃÊÀ½ç×îеÄÊý×ÖÐźŴ¦Àí¼¼Êõ·¢Õ¹£¬Ä¿Ç°ÊÇÈ«ÊÀ½çÐÔÄÜ×îºÃµÄÉñ¾¿ÆÑ§²âÁ¿ÏµÍ³²¢ÌṩÁ˸ü¼Ó¾«È·Óë¸É¾»µÄÐźÅÖÊÁ¿¡¢¸ü¸ßµÄ²ÉÑùÂÊ¡¢Ä£¿é»¯½â¾ö·½°¸£¬ºÍÔÚÊý×ÖÐźżӹ¤¹ý³ÌÖÐÀûÓÃ×îд¦ÀíÊÖ¶Î,ʹÆä¸ü¼Ó¾ßÓÐÁé»îÐÔºÍÀ©Õ¹ÐÔ¡£NeurOneÊÇÒ»¸ö¶à¹¦ÄÜϵͳ£¬¹ã·ºÓ¦ÓÃÓÚ²»Í¬µÄÈÏÖªÉñ¾¿ÆÑ§¡¢ÐÄÀíÓëÐÐΪ¿ÆÑ§ÒÔ¼°ÈËÒò¹¤³ÌÓ빤ЧѧµÈÑо¿ÁìÓò¡£
¶þ¡¢¶àģ̬ÄÔ¹¦ÄÜÑо¿£º NeurOneϵͳ¿ÉÒÔÓëfMRI¹¦ÄÜÐԺ˴ʲÕñ¡¢fNIRS¹¦ÄÜÐÔ½üºìÍâ¹âÆ×ÄÔ³ÉÏñ»òÕßTMS¾Â´Å´Ì¼¤Æ÷½áºÏ½øÐжàģ̬ÄÔ¹¦ÄÜʵÑéÑо¿£»NeurOneÌṩÁËרΪÓëTMS¾Â´Å´Ì¼¤Æ÷Ò»ÆðʹÓõŦÄÜÄ£¿é£¬ÓÐÌØÊ⻹Լ¼ÊõÔÚ¶ÌÑÓʱÇé¿öÏÂÀ´Ïû³ý´ÅÖÆÆ·Ó°Ïì¡£ÏȽøµÄÍ·ºÐÉè¼ÆÊ¹AC½»Á÷µçºÍDCÖ±Á÷µçÐźſɵ¥¶À»òͬʱ,еĴ´ÐÂTeslaºË´ÅÄÔµç·Å´óÆ÷¸øNeurOne´øÀ´MRI¼æÈÝÐÔ¡£
Èý¡¢¼¼Êõ¹¦ÄÜÌØµã£º NeurOneÌôÕ½´«Í³µÄÈÏÖªÉñ¾ÊµÑéÊÒERPϵͳ: 24Bit¸ß·Ö±æÂÊ Ã¿Í¨µÀ×î¸ß¿É´ï80,000Hz³¬¸ßËÙ²ÉÑùÂÊ ¸ß¾«¶È·Å´óÆ÷¼¼Êõ ¿ÉÉý¼¶ÎªNeurOneBrainstormϵͳ,×î¸ß´ï1200µ¼Áª NeurOneÉ豸¾ßÓкÜÃ÷ÏԵļ¼ÊõÁìÏÈÓÅÊÆ£¬¾ö²»ÒÔÎþÉüÊý¾ÝÖÊÁ¿À´×·ÇóͨµÀµÄÊýÁ¿¡¢Ëõ¶Ì×¼±¸Ê±¼ä»òÕß½µµÍ³É±¾¡£ÆäÖУ¬NeurOne·Å´óÆ÷ÿ¸ö80µ¼£¬°üÀ¨8¸öË«¼«µ¼Áª£¬»¹ÓÐ8µ¼High-levelÍâ½ÓÐźÅÊäÈë¡£ÓÉÓÚËüµÄƵ´ø×ã¹»¿í£¨DC¡«3500Hz£©¡¢²ÉÑùÂÊ×ã¹»¸ß£¨256-1200µ¼£¬Ã¿µ¼¿É´ï20000Hz£¬µ¥µ¼¼Ç¼×î¸ß¿É´ï80000Hz£©£¬»¹¿ÉÓÃË«¼«»òµ¥¼«Í¬Ê±¼Ç¼Ðí¶àÆäËûµÄÉúÀíÐźţ¨ÈçECGÐĵ硢EMG¼¡µç¡¢EEGÄÔµçµÈ£©£¬Ò»·½Ãæ¿ÉÒÔÈ¥³ýÐĵçºÍ¼¡µçµÄ¸ÉÈÅ£¬ÁíÒ»·½Ãæ¿ÉÒÔ½øÐÐÄԻ¹ý³ÌÓëÆäËûÉúÀíϵͳµÄ×ÛºÏÑо¿¡£Í¬Ê±NeurOneµÄ·Å´óÆ÷²ÎÊý×ã¹»¸ß£¬ÐÔÄÜ×ã¹»Îȶ¨£¬¿ÉÒÔ½øÐÐÌý¾õÄÔ¸ÉÓÕ·¢µçλµÄ¼Ç¼ºÍÑо¿¡£ÊäÈë×迹Ϊ1 Gohm£¬¹²Ä£ÒÖÖÆ±È 106 dB¡£ NeurOneÊǽ¨Á¢Ôڸ߱£Õæ¼Ç¼µÄ»ù´¡ÉÏ£¬Äܹ»ÌṩÍêÈ«ÔʼµÄ¸ß±£ÕæÊý¾Ý£¬²»ÐèÒªÆÁ±ÎºÍÂ˲¨£¬ÐźŲ»Ê§Õæ¡£
ËÄ¡¢ÄԵ糬ɨÃè¼¼Êõ NeurOneÄԵ糬ɨÃèϵͳÿ¸ö·Å´óÆ÷µÄHeadboxÓÉ64¸öµ¥¼«¡¢8¸öË«¼«ºÍ8¸öhigh levelÊäÈë½Ó¿Ú×é³É£¬¹²¼Æ80µ¼£¬Ã¿µ¼µÄ²ÉÑùÂÊÄÜ´ïµ½20000Hz£¬×î¸ß¿ÉÒÔ´ïµ½80000Hz¡£ÍÅÌ峬ɨÃèÄÔµç²âÊÔÆ½Ì¨Ã¿Ì×ϵͳ¿ÉÌṩ¶àÖÁ2-30¸ö·Å´óÆ÷£¨¹²¼Æ128/1200µ¼£©µÄе÷ͬ²½,²¢¿ÉÑ¡ÔñÖ§³ÖÊÓÆµÍ¬²½¡£NeurOneϵͳ×î¸ßÖ§³Ö1200¸ßµ¼Áª£¬²¢¿ÉÈ·±£ËùÓÐͨµÀµÄͬ²½²É¼¯¡£¾«ÐÄÉè¼ÆµÄÆô¶¯ºÍʱ¼äËø¶¨¹¦ÄÜÈ·±£ÏµÍ³ÖÐËùÓÐͨµÀÎÞÏàλƫ²î¡£ËùÓеÄͨµÀ¶¼Ê¹ÓøßÖÊÁ¿µÄ24λA/DÄ£ÄâÊý×ÖоƬÀ´´¦ÀíÊý¾Ý¡£
Îå¡¢¶à¹¦ÄÜÓ¦Ó㺡¡ 1¡¢HyperscanningÄԵ糬ɨÃèÑо¿: NeurOneÄԵ糬ɨÃèϵͳµÄÄ£¿é»¯Éè¼Æ¿ÉÒÔÌṩ¶à´ï4ÈËʵʱͬ²½½øÐÐÄÔ¹¦Äܳ¬É¨Ãè²âÊÔʹÓÃϵͳ£¬²¢Ö§³ÖÍêȫͬ²½ÊÓÆµµÄÉãÓ°»ú¡£Ê¹Óô´ÐµÄBrainstorm³¬É¨Ãè¼¼Êõ (Multi Syncbox)£¬Ö§³Ö¶à´ï10¸ö NeurOneÖ÷»úϵͳʵʱͬ²½£¬ÔÊÐí×î¶à30ÈËʹÓÃ30¸ö·Å´óÆ÷ͬʱ¹¤×÷¨C¾ùÓÉһ̨µçÄԼǼ¡£
2¡¢EEG-fNIRS¶àģ̬Ñо¿: NeurOne¶àģ̬ÄÔ¹¦ÄܲâÊÔϵͳ¿ÉÒÔºÍfNIRS£¨¸ßÃܶȽüºìÍâÄÔ¹¦ÄܳÉÏñϵͳ£©´îÅäʹÓ㬽«EEGºÍfNIRS½øÐÐÕûºÏ·¢»Ó¶þÕßµÄÓÅÊÆ£¬EEGµÄʱ¼ä·Ö±æÂʸߣ¬µ«Êǿռä·Ö±æÂʵͣ»fNIRSµÄʱ¼ä·Ö±æÂʵͣ¬ÊµÊ±ÐԽϲµ«Êǿռä·Ö±æÂʸߡ£ÎªÁË׼ȷ¡¢È«Ã桢ʵʱµÄ²âÁ¿´óÄÔÔÚÈÏÖª¹ý³ÌÖеĻ£¬ÊµÏÖÈ«Ãæ¡¢ÊµÊ±µÄÄÔ³ÉÏñ·½Ê½ÎÞÒÉÊÇÒ»ÖÖ¸üºÃµÄ²ßÂÔ¡£½áºÏEEGÓëfNIRSµÄ¶àģ̬ÄÔ³ÉÏñ¼¼ÊõÔÚÈÏÖªÉñ¾¿ÆÑ§Ñо¿ÖÐÓÐןܺõÄÓ¦ÓÃǰ¾°£¬Í¬Ê±»¹¿É´î½¨¶àģ̬ÄÔ-»ú½Ó¿Úϵͳ¡£
3¡¢EEG-fNIRS¶àģ̬ÄÔ»ú½Ó¿ÚÑо¿:´«Í³»ùÓÚµ¥Ò»Ä£Ì¬ÄÔµç(EEG)ÄÔ-»ú½Ó¿ÚÒ×ÊÜ»·¾³ÔëÉù¸ÉÈÅ¡¢·ÖÀྫ¶ÈµÍµÈÎÊÌâ,ÔÚEEGÄÔ-»ú½Ó¿ÚµÄÑо¿»ù´¡ÉÏ,ÒýÈ빦ÄܽüºìÍâ¹âÆ×³ÉÏñ(function NearInfrared Spectroscopy,fNIRS)¼¼Êõ,¿ÉÒÔ×ÔÐÐÉè¼ÆEEG-fNIRS¶àģ̬ÄÔ-»ú½Ó¿ÚµÄʵÑ鷶ʽ,Ñо¿×îÖØÒªµÄÌØÕ÷ÌáÈ¡Óë·ÖÀà»·½Ú£¬Í¬Ê±SIMULINKÇý¶¯³ÌÐò¿ÉÔÚ¶©µ¥ÖÐÑ¡¹º£¬²¢ÌṩBCIÄÔ»ú½Ó¿ÚÓ¦ÓóÌÐò: BCI2000¿ÉÃâ·ÑÌṩ¸øNeurOneÓû§¡£
4¡¢EEG-TMS¶àģ̬Ñо¿: NeurOne¶àģ̬ÄÔ¹¦ÄܲâÊÔϵͳ¿ÉÒÔºÍTMS£¨¾Â´Å´Ì¼¤Æ÷£©´îÅäʹÓ᣸߶¯Ì¬ÊäÈ뷶Χ£¨+/-430mVµÄÖ±Á÷µçģʽÒÔ¼°+/-86mVµÄ½»Á÷µçģʽ£©£¬½Ï´óµÄÄ£Äâ´ø¿í£¨Ö±Á÷Êä³ö3500HZ£©£¬ÈÃTMS±£³Ö½ÏµÍµÄαӰ£¬Ê¹µÃ·ÖÎö´óÄԻµÄDZ·üÆÚ¸ü¶Ì¡£´ËÍ⣬TMSÓµÓÐÓ²¼þÈõÒô¹¦ÄÜÒÔ¼°ÔÚÏßαӰÏû³ýµÄÈí¼þ¹¦ÄÜ¡£´ËÍâÎÒÃÇÔö¼ÓÁËEEG²ÉÑùͬ²½´¥·¢Ð¹¦ÄÜ¡£´¥·¢Æ÷Óɴ̼¤ÏµÍ³Èí¼þ·¢³ö£¨ErgoLAB´Ì¼¤±àÒëÈí¼þ¡¢PresentationÈí¼þ, SuperlabÈí¼þ, E-PrimeÈí¼þ£©£¬ÕâЩ´¥·¢ÐźÅÄܹ»Í¨¹ýNeurOneÖ÷¿ØÆ÷´«µ½TMSÉ豸ÉÏ¡£NeurOne¿ÉÒÔÔÚ³ÖÐøµÄEEG²ÉÑùÐźÅÖз¢³ö´¥·¢Âö³å£¬²úÉú¸ü¾«È·µÄTMS£¬¼õÉÙαӰ£¬¸üÈÝÒ×½øÐÐαӰȥ³ý¡£ NeurOne½áºÏTMS°¸ÀýÓ¦Óãºhttp://www.kingfar.cn/newsShow_88.html
5¡¢EEG-fMRI¶àģ̬Ñо¿: NeurOne Tesla¶àģ̬ÄÔ¹¦ÄܲâÊÔϵͳʹµÃͬʱ²âÁ¿MRIºÍEEG³ÉΪ¿ÉÄÜ¡£ÀûÓÃNeurOne SyncboxEEGËù»ñµÃµÄÊý¾ÝºÍMRIɨÃèÊÇͬ²½µÄ(ÀýÈç4»ò10MHz)¡£¸ß¶¯Ì¬ÊäÈ뷶Χ(+/- 430 mVµÄÖ±Á÷µçģʽºÍ +/-86 mVµÄ½»Á÷µçģʽ)½áºÏÄ£Äâ´ø¿í(Ö±Á÷Êä³ö3500 Hz) ,ʹÀûÓøßÌݶÈÁ¦¶È»ñµÃ¾«È·ÐźźÁÎÞ·çÏÕ¡£
Ó¦ÓÃÁìÓò£º EEG/EP²âÁ¿ ERPÑо¿ EEG +TMS½áºÏ¶àģ̬ÄÔ¹¦ÄÜÑо¿ EEG +fMRI½áºÏ¶àģ̬ÄÔ¹¦ÄÜÑо¿ ¶àͨµÀEMG¼¡µçͼÑо¿ Ⱥ×鳬ɨÃèÑо¿£¨¶à´ï4ÈË4ÊÓÆµÉãÏñ»úÍêȫͬ²½£© ÆäËûÉñ¾¿ÆÑ§µÄ²âÁ¿ ÆäËûÐÄÀí²âÁ¿
NeurOne·Å´óÆ÷²ÎÊý£º •ÿ¸öHeadbox ÓÐ64µ¼µ¥¼«µ¼Áª£» •ÿ¸öHeadbox ÓÐ16µ¼Ë«¼«µ¼Áª£» •ÿ¸öHeadbox ÓÐ16µ¼High Level µ¼Áª£» •²ÉÑùÂÊ£º512µ¼Í¬Ê±²É¼¯£¬Ã¿µ¼¿É´ï20,000 Hz £» •ËùÓе¼Áª¾ùͬ²½²É¼¯Ðźţ¬×î´óÖ§³Ö1200¸ßµ¼Áª£¬ •Ö§³Ö³¬É¨Ãè¼¼ÊõHyperscanning×î¶àÖ§³Ö30ÈËͬ²½²É¼¯ÍÅÌåÄÔµçÊý¾Ý£» •Ö§³Ö¶àģ̬¼¼Êõ£¬º¬EEG-TMS£¬EEG-fNIRS£¬EEG-fMRIµÈÑо¿¼¼Êõ·½°¸ •A/DResolution£º24 Bit £» •ÊäÈë×迹£º1 GOhms £» •¹²Ä£ÒÖÖÆ±È£¨CMRR£©£º106 dB £» •´ø¿í£¨Bandwidth£©£ºDC ¡« 3500 Hz £» •µÍͨÂ˲¨£ºDC£¨10000 Hz£©£»-3 dB£¨7000 Hz£©£» •¸ßͨÂ˲¨£º -3 dB£¨0.16 Hz£©£» •ÊäÈëÔëÉù£¨InputNoise.£©£¨DC Mode£©£º<0.8uV RMS (0-200 Hz)£¬ <2.0uV RMS(DC-3500 Hz) £» •ÊäÈ뷶Χ£¨FullScale Input Range£©£¨DC Mode£©£º+/- 430 mV £» •ϵͳÔöÒæ£¨SystemGain£©£¨DC Mode£©£º10 £» •ÁéÃô¶È£¨Sensitivity£©£¨DC Mode)£º51 nV/bit £» •ÊäÈëÔëÉù£¨InputNoise.£©£¨AC Mode£©£º<0.6uV RMS (0.16-200 Hz)£¬ <1.5uV RMS (0.16-3500 Hz) £» •ÊäÈ뷶Χ£¨FullScale Input Range£©£¨AC Mode£©£º+/- 4.3 mV £» •ϵͳÔöÒæ£¨SystemGain£©£¨AC Mode£©£º50 £» •ÁéÃô¶È£¨Sensitivity£©£¨AC Mode£©£º0.51 nV/bit £» •Êý×Ö»¯£¨TTL£©ÊäÈ룺8 Bit·Ç¸ôÀëÊäÈë´¥·¢£¬2¸ö¸ôÀëÊäÈë/Êä³ö •High Level ÊäÈ뷶Χ£º+/- 5 V £»»ò+/- 10 V •×迹£º1K Ohm ¡« 50 K Ohm £» •Headbox Ìå»ý£¨h x w x d£©£º20 x 7 x 16cm, ÿ 64 µ¼£» •Headbox ÖØÁ¿£º0.68 kg¡£ •Main unitÌå»ý£¨H x W x D£©£º33¡Á12¡Á27 cm,160µ¼ÏµÍ³Ö÷»ú •Main unitÖØÁ¿£º3.6 •°²È«¹æ·¶£ºEN60601-1£¬EN 60601-1-1£¬EN 60601-1-2 EN60601-1-4£¬EN60601-2-26
NeurOneÓû§Çë×¢Ò⣺ ×¢Òâ ¨C ½öÓÃÓÚ¿ÆÑУ¬²»ÓÃÓÚÕï¶Ï¹ý³Ì,É豸¿ÉÓÃÓÚ·ÇÁÙ´²ÊµÑéÑо¿¡£
PUBLICATIONS USING NEURONE EEG/ERP ORNEURONE TESLA : 1. A platform for realtime processing of biosignalsfor monitoring purposes. PITKÄNEN,PAAVO. Master of Science Thesis. Tampere University of Technology. May 2012. InFinnish 2. A New Platform for Realtime BCI Applications. Paavo Pitkänen1,2,Jukka Kinnunen2, Tarmo Lipping1 (IEEE,Senior Member). 1 Tampere University Of Technology, 2 Mega Electronics Ltd. Poster at Berlin BCI meeting 2012 3. Visual ERP P3 amplitude and latency in standaloneand embedded visual processing task. Conf Proc IEEE Eng Med Biol Soc. 2011;2011:781-4.doi: 10.1109/IEMBS.2011.6090179. Korpela J, Huotilainen M. Brain Work ResearchCentre, Finnish Institute of Occupational Health, Helsinki, Finland. jussi.korpela@ttl.fi 4. The effect of automatic blink correction onauditory evoked potentials. Korpela,J. ; Brain Work Res. Centre, Finnish Inst. of Occupational Health, Helsinki,Finland ; Vigario, R. ; Huotilainen, M. 10.1109/EMBC.2012.6346009 5. Breakfast high in whey protein or carbohydratesimproves coping with workload in healthy subjects. Nora Sihvola a1, Riitta Korpela a1, Andreas Henelius a2, Anu Holm a2 a3,Minna Huotilainen a2, Kiti M¨¹ller a2,Tuija Poussa a4, Kati Pettersson a2,Anu Turpeinen a5 and Katri Peuhkuri a1 c1.a1 Institute of Biomedicine, Medical NutritionPhysiology, Pharmacology, University of Helsinki, PO Box 63, HelsinkiFIN-00014, Finland. a2 Finnish Institute of Occupational Health,Brain and Technology Team, Topeliuksenkatu 41 aA, Helsinki FIN-00250, Finland. a3 Department of Clinical Neurophysiology, Hospital District of Satakunta,Sairaalantie 3, Pori FIN-28500, Finland a4 Stat-Consulting,Vahverokatu 6, Nokia FIN-37130, Finland a5 ValioLimited, PO Box 30, VALIO, Helsinki FIN-00039, Finland British Journal ofNutrition, 2013 6. Pilot Study ofAcupuncture Point Laterality: Evidence from Heart Rate Variability. Guangjun Wang, Yuying Tian, ShuyongJia,Wenting Zhou, and Weibo Zhang. Institute ofAcupuncture and Moxibustion, China Academy of Chinese Medical Sciences, 16Dongzhimennei, Nanxiaojie, Dongchen District, Beijing 100700, China Evidence-BasedComplementary and Alternative Medicine. Volume 2013 (2013), Article ID 476064,7 pages http://www.hindawi.com/journals/ecam/aip/476064/
7. Algorithm forautomatic analysis of electro-oculographic data. Kati Pettersson1*, Sharman Jagadeesan1, Kristian Lukander1,Andreas Henelius1, Edward Hæggström2 andKiti M¨¹ller1 1Brain Work Research Center, FinnishInstitute of Occupational Health, Topeliuksenkatu 41aA, Helsinki 00250,Finland. 2Electronics Research Laboratory, Departmentof Physics, University of Helsinki, P. O. Box 64, Gustaf Hällströmin katu 2,Helsinki FIN-00014, Finland. BioMedicalEngineering OnLine 2013 12:110. 8. Brain-statedependent brain stimulation: Real-time EEG alpha band analysis using slidingwindow FFT phase progression extrapolation to trigger an alpha phase locked TMSpulse with 1 millisecond accuracy. Christoph Zrenner,Johannes T¨¹nnerhoff , Carl Zipser, Florian M¨¹ller-Dahlhaus , Ulf Ziemann Center forNeurology, T¨¹bingen University, Hoppe-Seyler-Str. 3, 72076 T¨¹bingen, Germany BrainStimulation: Basic, Translational, and Clinical Research in Neuromodulation:Volume 8, Issue 2, A1-A10, 169-438 9. Behavioral andelectrophysiological evidence for fast emergence of visual consciousness. Henry Railo1,2,3,*,Antti Revonsuo1,2,3,4 and Mika Koivisto1,2,3 1Department of Psychology, University ofTurku, 20014, Finland; 2Centre for Cognitive Neuroscience, University of Turku, 20014, Finland;3Brain and Mind Centre, University of Turku,20014, Finland; 4School of Bioscience, University of Skövde,SE-54128, Sweden Neuroscience ofConsciousness, 2015, 1¨C12 10. Fastdetermination of MMN and P3a responses to linguistically and emotionallyrelevant changes in pseudoword stimuli Satu Pakarinen,Laura Sokka, Marianne Leinikka, Andreas Henelius, Jussi Korpela,Minna Huotilainen Finnish Institute ofOccupational Health, Helsinki, Finland NeuroscienceLetters 577 (2014) 28¨C33 11. Alterationsin attention capture to auditory emotional stimuli in job burnout: Anevent-related potential study Laura Sokka a, Minna Huotilainen a, Marianne Leinikka a, Jussi Korpela a, Andreas Henelius a,Claude Alain b,c, Kiti M¨¹ller a,Satu Pakarinena a Finnish Institute of Occupational Health,Topeliuksenkatu 41 a A, 00250 Helsinki, Finland b Rotman Research Institute, Baycrest Centrefor Geriatric Care, 3560 Bathurst Street, Toronto, Ontario, Canada M6A 2E1 c Department of Psychology, University ofToronto, Toronto, Ontario, Canada InternationalJournal of Psychophysiology 94 (2014) 427¨C436 12. Brain-statedependent non-invasive brain stimulation using closed-loop real-time EEG signalanalysis to trigger a TMS pulse with millisecond accuracy C. Zrenner, J.T¨¹nnerhoff, C. Zipser, F. M¨¹ller-Dahlhaus, U. Ziemann University ofT¨¹bingen, Center of Neurology, T¨¹bingen, Germany SocietyProceedings / Clinical Neurophysiology 126 (2015) e63¨Ce170 13. BilateralHegu Acupoints Have the Same Effect on the Heart Rate Variability of theHealthy Subjects Wang Guangjun, TianYuying, Jia Shuyong, ZhouWenting, and ZhangWeibo Institute ofAcupuncture and Moxibustion, China Academy of Chinese Medical Sciences, Beijing 100700,China Hindawi PublishingCorporation Evidence-BasedComplementary and Alternative Medicine Volume 2014, ArticleID 106940, 5 pages (http://dx.doi.org/10.1155/2014/106940) 14. AcupunctureRegulates the Heart Rate Variability Guangjun Wang,Yuying Tian, Shuyong Jia, Wenting Zhou, Weibo Zhang Institute ofAcupuncture and Moxibustion, China Academy of Chinese Medical Sciences, Beijing, China J AcupunctMeridian Stud 2015;8(2):94-98 15. Closed-LoopNeuroscience and Non-Invasive Brain Stimulation: A Tale of Two Loops Christoph Zrenner,Paolo Belardinelli, Florian M¨¹ller-Dahlhaus and Ulf Ziemann Brain Network andPlasticity Laboratory, Department of Neurology and Stroke and Hertie-Institutefor Clinical Brain Research, University of T¨¹bingen, T¨¹bingen, Germany Frontiers inCellular Neuroscience, April 2016, Volume 10, Article 92 16. Physiologicalprocesses non-linearly affect electrophysiological recordings duringtranscranial electric stimulation Noury, N., et al.,NeuroImage (2016), http://dx.doi.org/10.1016/j.neuroimage.2016.03.065 17. Job burnout is associated with dysfunctions inbrain mechanisms ofvoluntary and involuntary attention Laura Sokka, Marianne Leinikka, JussiKorpela, Andreas Henelius, Lauri Ahonen,Claude Alain, Kimmo Alho, MinnaHuotilainen, http://dx.doi.org/10.1016/j.biopsycho.2016.02.010 18. Shifting ofattentional set is inadequate in severe burnout: Evidence from an event-relatedpotential study Laura Sokka, MarianneLeinikka, Jussi Korpela, Andreas Henelius, Jani Lukander, Satu Pakarinen, KimmoAlho, Minna Huotilainen. PII: S0167-8760(16)30853-4 DOI: doi:10.1016/j.ijpsycho.2016.12.004 |