²úÆ·ÐͺÅ
|
Banggoo® ADC 1000P
|
¿Õ¼äÕ¼ÓÃ
|
2U
|
¹æ¸ñ
|
443mm¿í*560mmÉî*88mm¸ß
|
ÖØÁ¿
|
42°õ
|
ÍøÂç½Ó¿Ú
|
4¸öǧÕ×¹âÏ˶˿ڡ£
|
±êÅä8¸ö10/100/1000 Base-TÒÔÌ«Íø¶Ë¿Ú£¬¿ÉÀ©Õ¹ÖÁ16¸ö¡£
|
×î´ó¿ÉÀ©Õ¹ÖÁ32¸öǧÕ׶˿ڣ¨µç¿Ú/¹â¿Ú£©¡£
|
1¶ÀÁ¢¹ÜÀí½Ó¿Ú¡£
|
CPU
|
64λ¶àºËCPU¡£
|
CPUÊýÁ¿
|
1¿Å¡£
|
USB½Ó¿Ú
|
2¸ö¡£
|
ÍøÂç¶Ë¿ÚÌØÐÔ
|
Ö§³Ö802.1q VLAN£¬VLAN×î´óÊýÁ¿²»ÉÙÓÚ4094¸ö£»¶Ë¿Úģʽ֧³ÖAccessÒÔ¼°Trunkģʽ£»Ö§³ÖIP͸Ã÷ģʽ£»Ö§³ÖIPV6¡£
|
¶Ë¿ÚÖ§³Ö±ê×¼
|
10Base-T/100Base-T (IEEE 802.3,802.3u)/1000Base-T (IEEE 802.3ab)/1000Base-SX (IEEE 802.3z)£»802.1q VLAN, 802.3x Flow Control, IEEE 802.1p, TCP/IP, UDP, ICMP, HTTP, SNMP, STP(IEEE 802.3d)£»Fast Ether channel/Gigabit Ether Channel (IEEE 802.3ad), OSPF, RIP, BGP, Qos/ToS,Jumbo frames (up to 16kb).
|
ÄÚ´æ
|
4G
|
Æß²ãÐÂÔö´¦ÀíÄÜÁ¦
|
150,000
|
ËIJãÐÂÔö´¦ÀíÄÜÁ¦
|
120,000
|
×î´ó²¢·¢Á¬½ÓÊý
|
8,000,000
|
Æß²ãÍÌÍÂÂÊ
|
2Gbps
|
ÐéÄâIPµØÖ·Êý
|
²»ÏÞ
|
ÄÚÈÝѹËõÍÌÍÂ
|
1.5Gbps
|
SSL¼Ó½âÃܼ°SSL¼ÓËÙ
|
15,000TPS
1,000,00²¢·¢Á¬½ÓÊý
Ö§³Ö¼¯³ÉÈÏÖ¤ºÍÔÙ¼ÓÃÜ
|
SSL¶Ô³Æ¼ÓÃÜÁ÷Á¿
|
2Gbps¶Ô³Æ¼ÓÃÜÁ÷Á¿
|
HTTPÄÚÈÝ»º´æ
|
Ö§³Ö¡£
|
ÄÚÈÝ»º´æÄÚ´æ¿Õ¼ä
|
3G
|
É豸ÉúÃüÖÜÆÚ
|
ÒªÇóͶ±ê²úƷΪÏÖÓÐÆ½Ì¨ÏúÊÛ²úÆ·£¬ÔÚ¹Ù·½ÍøÕ¾ÉÏÄÜÕÒµ½Ïà¶ÔÓ¦µÄͶ±ê²úÆ·Ðͺţ¬²¢Ìṩ¹Ù·½²ÊÒ³×ÊÁϽéÉÜ¡£
|
ÖÇÄÜÁ÷Á¿¹ÜÀíÓïÑÔÖ§³Ö
|
TCScriptΪרÓÐÖÇÄÜÁ÷Á¿¹ÜÀíÓïÑÔ£¬¿ÉʵÏÖÉî¶ÈÄÚÈݼì²â£¬ÔÊÐí¸ù¾ÝÈκÎÇëÇóµÄÈÎÒâ²ÎÊýʵʩ¸ºÔؾùºâ¡¢»á»°±£³ÖµÈÁ÷Á¿¹ÜÀí¡£
|
Web Service/XML
|
Ö§³Ö.NET£¬SOAP£¬XML-RPC£¬J2EE¡£
|
API½Ó¿Ú
|
Ìá¹©È«ÃæµÄÍøÂç±à³Ì¶Ë¿Ú£¬Ö§³Ö¹Ø¼üÈÎÎñÓ¦ÓᢵÚÈý·½½â¾ö·½°¸ºÍÍøÂçÁ÷Á¿¹ÜÀí¼¼Êõ¸ßЧµØ½áºÏÆðÀ´£¬ÆóÒµ¿ÉÒÔʵÏÖÀͶ¯Ãܼ¯Ð͹¦ÄܵÄ×Ô¶¯»¯£¬½µµÍά»¤¹ÜÀíÒÔ¼°½â¾ö·½°¸¿ª·¢µÄÏà¹Ø³É±¾£»²¢À©Õ¹ÍøÂç»·¾³£¬ÒÔÈ·±£ÓëÆäËùÖ§³ÖµÄÓ¦Óøüе÷µØÔË×÷£¬ÌṩSDK¿ª·¢°ü¡£
|
»á»°±£³Ö·½Ê½
|
Ö§³Ö»ùÓÚÔ´/Ä¿µÄIPµØÖ·¡¢»ùÓÚcookies»òÌØ¶¨µÄÓ¦ÓÃcookies¡¢»ùÓÚSSL»á»°ID¡¢ÒÔ¼°»ùÓÚÇëÇóÖеÄÈÎÒâ²ÎÊý»òÈÎÒâÖµµÄ¶àÖֻỰ±£³Ö·½Ê½¡£
|
¸ºÔؾùºâËã·¨
|
Ö§³ÖÂÖѯ¡¢¼ÓȨÂÖѯ¡¢×îÉÙÁ¬½ÓÊý¡¢¼ÓȨ×îСÁ¬½ÓÊý¡¢×î¿ìÏìӦʱ¼ä¡¢CPUÀûÓÃÂÊ¡¢Ëæ»ú¡¢ÖÇÄÜÔ¤²âµÈ¶àÖÖ¸ºÔؾùºâËã·¨¡£
|
·þÎñµÈ¼¶¹ÜÀí
|
Ö§³ÖSLA·þÎñµÈ¼¶¹ÜÀí£¬¿É»ùÓÚÿһ¸ö·þÎñ¶Ô²»Í¬¼¶±ðµÄÓû§Ìṩ²îÒìÐÔ·þÎñ£¬·þÎñÐÔÄܵø³öSLAÔ¼¶¨Ê±¿É×Ô¶¯±¨¾¯¡¢¶¯Ì¬µ÷Õû·þÎñÆ÷³Ø×ÊÔ´½øÐÐÓÅ»¯²¢¼ÇÈëÈÕÖ¾¡£
|
WEB¹ÜÀí½çÃæ
|
Ö§³ÖÖÐÓ¢ÎÄWEB¹ÜÀí½çÃæ£¨²»Í¨¹ý²å¼þ·½Ê½ÊµÏÖ£©
|
¸ß¿ÉÓÃ
|
Ö§³ÖË«»úÈȱ¸£¬Ö§³ÖN+M¶à»úÈßÓ࣬×î¶àÖ§³Ö64̨,²¢ÇÒÖ§³Ö¿ç²úÆ·Ðͺš£Çл»Ê±¼ä<200ms
|
Ö§³ÖʵÏÖN̨É豸Active£¬M̨É豸BACKUPµÄÈÎÒâ×éºÏ¡£ ¿ÉÒÔʵÏÖ¡°Ö÷+±¸¡±Ä£Ê½¡¢¡°Ö÷+Ö÷¡±Ä£Ê½¡¢¡°¶àÖ÷+¶à±¸¡±Ä£Ê½¡¢¡°È«Ö÷¡±Ä£Ê½£¬²¢ÊµÏÖÐÔÄÜÏßÐÔÔö³¤¡£
|
Ç°Ãæ°åLCDÏÔʾ
|
Ö§³ÖÇ°Ãæ°åLCDÖ÷Ҫϵͳ²ÎÊý¼à¿Ø£¬Ö§³ÖʹÓÃLCDÃæ°åÉèÖùÜÀí¿ÚIPµØÖ·¡£
|
°²È«µÄ¹ÜÀí
|
¿ÉÒÔͨ¹ýHTTPS¡¢SSH½øÐа²È«µÄÔ¶³Ì¹ÜÀí£¬±¾µØ¿ÉÒÔͨ¹ýCONSOLEÖն˽øÐйÜÀí¡£
|
Óû§È¨ÏÞ¹ÜÀí
|
Ö§³Ö¿ÉÒÔ¿ØÖƵ½¹ÜÀí½çÃæµÄÿһÏî¡£¿ÉÒÔÑϸñ¿ØÖÆÃ¿¸ö¹ÜÀíÔ±¿ÉÅäÖúͲ鿴µÄ¾ßÌåÏîÄ¿¡£
|
ʵʱʼþ±¨¾¯ÏµÍ³
|
Ö§³Ö¸ù¾ÝÓû§ÐèÇóÖÆ¶¨ÈÎÒâʼþ£¬²¢µÚһʱ¼ä°Ñʼþͨ¹ýemail¡¢syslog¡¢snmp trapµÈ·½Ê½Í¨Öª¹ÜÀíÔ±¡£
|
ͼ±í
|
Ö§³Ö×Ô¶¨Òåͼ±í£¬Ö§³Ö180ÖÖ²»Í¬²ÎÊýµÄʵʱͼ±í£¬Ö§³Öweb·½Ê½µ¼³öͼ±íÊý¾Ý¡£
|
É豸±¾Éí±£³Ö1ÄêµÄÀúÊ·Êý¾Ý£¬Ö§³Öweb·½Ê½µ¼³öͼ±íÊý¾Ý¡£
|
ÅäÖÃÎļþ¹ÜÀí
|
Ö§³Öweb·½Ê½±¸·ÝÅäÖÃÎļþ£¬²¢ÇÒ¿ÉÒÔ¶Ô²»Í¬ÅäÖÃÎļþ½øÐбȽϣ¬ÁгöÅäÖÃÎļþ²»Í¬Ö®´¦¡£
Ö§³Öweb·½Ê½µ¼ÈëºÍµ¼³öÅäÖÃÎļþ¡£
|
µÚÈý·½³ÌÐò¼æÈÝÐÔ
|
Ö§³Öµ¼ÈëµÚÈý·½³ÌÐò£¬Í¨¹ýÉ豸½øÐе÷Ó᣿ÉÖ§³ÖÓïÑÔ£ºperl¡¢java¡¢shellµÈ¡£
|
µç´Å·øÉä
|
FCC, CFR 47 Part 15, Subpart A ANSI C 63.4D11.4 1991, VCCI Class 1, FCC OST 55, CISPR 16,CISPR 22, CSA C 108.8-M 1983 (R1989), EN5502, CE, EN6100-3-2, EN60555-2
|
°²È«ÈÏ¿É
|
UL 1950, CUL, DIN/VDE0805, CSA22.2, No.950-93, IEC 950, EN60950,TUV EMKO-TSE(74-SEC)207/94 Nordic Deviations to EN60950
|
»·¾³
|
¹¤×÷ζȣº5~40¡æ£»
¹¤×÷Ïà¶Ôʪ¶È£º20%~90%£»
ÎÞÀäÄý¡£
|
µçÔ´
|
ÈȲå°ÎÈßÓàPSU£»
ÊäÈëµçѹ£º90-240VAC +/- 10%
×î´ó¹¦ºÄ£º350W
|